Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Chinese Journal of Radiology ; (12): 304-307, 2017.
Article in Chinese | WPRIM | ID: wpr-515266

ABSTRACT

Objective To compare the image quality and radiation dose of CTA of the kidney in patients using routine CT and the spectral imaging combination of different scanning protocols with the adaptive statistical iterative reconstruction 2.0 algorithm (ASIR 2.0). Methods A total of 90 patients who had undergone a CTA of the kidney were divided into three groups (A, B and C), with 30 patients in each group. Group A underwent a routine CT examination, and the scan parameters are:120 kVp, 30 to 650 mA, rotation time 0.5 s/r, scan FOV 50 cm × 50 cm;while groups B and C underwent spectral imaging protocol 1 and 2, the scan parameters of spectral imaging protocol 1 and 2 are:rapid dual kVp (80-140 kVp) switching in 0.25 ms, 375 mA and 360 mA, rotation time 0.7 s/r and 0.6 s/r, scan FOV 36 cm × 36 cm and 32 cm × 32 cm, respectively. All images were reconstructured using ASIR 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the kidney CTA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by two independent radiologists. The CT dose index (CTDIvol) and dose-length product (DLP) were recorded, and the mean value was calculated. The DLP was converted to the effective dose (ED). All data were compared with Kruskal-Wallis test and one-way ANOVA. Results The energy level of 49 to 56 keV was found to provide the best CNR for displaying CTA of the kidney. There were significant differences in CT values, noise, SNR, CNR and subjective score between groups B, C and A (P0.05). There were significant differences in ED among groups A, B and C (P<0.05), and the ED of groups A, B and C were (8.2±1.2), (5.2± 0.9) and (4.4 ± 0.7) mSv, respectively. Conclusion Spectral imaging with different scanning protocols can more effectively reduce the radiation dose than the routine CT scan mode for a kidney CTA while still maintaining diagnostic image quality, and protocol 2 of spectral imaging in our study is recommended.

2.
Journal of Biomedical Engineering ; (6): 1019-1022, 2007.
Article in Chinese | WPRIM | ID: wpr-346020

ABSTRACT

QRS complex has its distinct characteristics as compared with other waves in Electrocardiogram (ECG). In this paper is introduced a kind of algorithm to identify the R waves, which combines forward-backward difference algorithm, half-wave width algorithm and R-R interval algorithm. The algorithm is simple and reliable. It is in possession of the ability of anti-interference such as baseline drifting, high P waves or high T waves, and severe high-frequency interference. The average accuracy for identification is higher than 99.5%. The results of the experiment and the analyses are also presented.


Subject(s)
Humans , Algorithms , Electrocardiography , Methods , Numerical Analysis, Computer-Assisted , Signal Processing, Computer-Assisted
3.
Journal of Biomedical Engineering ; (6): 449-452, 2007.
Article in Chinese | WPRIM | ID: wpr-357679

ABSTRACT

In this paper is presented the Lorenz plot, the qualitative analyses and quantitative parameters of the plot. The long axis vs short axis(LVS) parameter is given. Atrial Fibrillation Electrocardiogram (AF ECG) is compared with sinus ECG by use of Lorenz plot. Then the difference in their plots and the parameter of LVS is pointed out. Lorenz plot finding is useful for the AF disease in automatic diagnoses of ECG signals.


Subject(s)
Humans , Atrial Fibrillation , Diagnosis , Electronic Data Processing , Methods , Electrocardiography, Ambulatory , Methods , Heart Rate , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL